There are two ways to make the connection to the main gas line:
A. The hotplate can be connected with rigid pipe as specified in AS5601 table 3.1.
B. The hotplate can be connected with a Flexible Hose, which complies with AS/NZS 1869 (AGA Approved),
10mm ID, class B or D, no more than 1.2m long and in accordance with AS5601.
WARNING: Ensure that the hose assembly is restrained from accidental contact with the flue or flue outlet of
an underbench oven and it does not contact the hot surfaces of the hotplate, oven, dishwasher or other
separate appliance that may be installed underneath or next to the hotplate. The hose should not be
subjected to abrasion, kinking or permanent deformation and should be able to be inspected along its entire
length. Unions compatible with the hose fittings must be used and connections tested for gas leaks.
The supply connection point must be accessible with the appliance installed. Fit the supplied elbow and
gasket as shown in Fig.20. The gas inlet connection has a 1/2" BSP male thread. When making the
connection, take care not to apply excessive stress by counterbalancing tightening force. Ensure that the
available gas supply is the same as the gas type label affixed to the base of the hob. If not, contact
Bertazzoni for a Gas Conversion Kit. The gas supply pressure must be adjusted in accordance with the data
label for the gas type.
Natural Gas
The natural gas regulator supplied must be fitted for natural gas. Ensure the arrow on the regulator points
towards the direction of the gas flow. The test point pressure must be adjusted to 1.00 kPa with the largest
burner operating on maximum flame.
Propane Gas
Fit the Propane Gas test point assembly (supplied in the gas conversion kit). An AGA Approved gas
regulator suitable for a supply pressure of 2.75kPa should be part of the gas tank supply.
ELECTRICAL CONNECTION
The appliance is equipped with a 1.2 m. cable with 3 wires ready for connection to a dedicated 3 wire
grounded power supply/junction box: (fig 19).
Voltage 240 V AC, Frequency 60Hz. Max Current: 3700W /15.5 A
brown wire: connect to L1 (hot)
---------------: connect to L1 (hot)
blue wire: connect to N (neutral)
Yellow/Green wire: connect to GND (ground)
A dedicated line and junction box should be used to connect the oven to a 20 A circuit.
When connecting the cable directly to the mains, connection to the electricity supply must be made by an
authorised person in accordance with the Wiring Rules AS/NZS3000. The installation must include a suitable
isolating switch with a minimum contact opening of 3mm between the appliance and the mains. The isolating
switch should be sized according to the load on the data label and should comply with current regulations
(the earth wire should not be interrupted by the circuit breaker).
Before making the connection check that:
the switch, wiring and electrical system can support the appliance load (see data plate);
the power supply system has an efficient earthing connection which complies with the provisions of
current regulations;
the power outlet or omnipoar circuit-breaker is easily accessible once the cooker has been installed.
WARNING: If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.